Generator diesel cum machina Cummins 20KVA-1600KVA
Officina generatorum diesel Walter nunc potest praebere vim stabilem et completam in omnibus campis potentiae (e.g., ferrivia, fodinae, valetudinaria, petroleum, petrificatio, communicationes, locationes, gubernatio, officinae et res immobiles, etc.).
Generator Cummins machinam Cummins ut potentiam accipit, cuius potentia a 20kva ad 1500kva variat.
Cummins est praecipua fabrica motorum cum magnis sumptibus et efficacia. Celeberrima est propter parvum consumptionem cibustibilis, magnam firmitatem, et servitium cautionis globalis.
Pro alternatoribus, habemus Stamford, Marathon, et China, quod clientibus nostris libere eligere facit.
Accessiones Standard generatoris Cummins:
1. Machina Cummins
2. Alternator Stamford (alternator Sinensis pro optione)
3. Tabula moderandi DEEPSEA DSE3110
4. basis altae qualitatis.
5. Systema Anti-Vibrationis Impositum
6. Accumulator et caricator accumulatoris
7. Silentiator industrialis et tubus exhaustorius flexibilis
8. Instrumenta Cummins
Commodum Generatoris Cummins Set:
1. Servitium Garantiae Globalis
2. stabilis potentiae perfunctio
3. operatio facilis et tuta
4. GENERATOR CUMMINS facile conservatur et reparatur, diuturna efficacia cum longa vita utili praebet.
5. Venditiones directae officinae qualitatem cum pretio competitivo habent.
6. Cum certificatis ISO9001 CE SGS BV
7. Generatores Diesel Partes substitutoriae pretio minore praesto sunt.

Parametri Technici 50Hz
| Modellum Generatoris | Generator (KVA) | Machina Cummins | Alternator Stamfordensis | |
| Prim Power | Potestas Subsidiaria | Modelus Machinae | Modelus Alternatoris | |
| W-DC20M-1 | 20KVA | 22KVA | 4B3.9G1 | PI 144D |
| W-DC20-1 | 20KVA | 22KVA | 4B3.9G2 | PI 144D |
| W-DC25M-1 | 25KVA | 28KVA | 4B3.9G1 | PI 144E |
| W-DC25-1 | 25KVA | 28KVA | 4B3.9G2 | PI 144E |
| W-DC30M-1 | 30KVA | 33KVA | 4BT3.9-G1 | PI 144G |
| W-DC30-1 | 30KVA | 33KVA | 4BT3.9-G2 | PI 144G |
| W-DC40M-1 | 40KVA | 44KVA | 4BT3.9-G1 | PI 144J |
| W-DC40-1 | 40KVA | 44KVA | 4BT3.9-G2 | PI 144J |
| W-DC50-1 | 50KVA | 55KVA | 4BTA3.9-G2 | UCI 224E |
| W-DC100M-1 | 100KVA | 110KVA | 6BT5.9G1 | UCI 224C |
| W-DC100-1 | 100KVA | 110KVA | 6BT5.9G2 | UCI 224C |
| W-DC120-1 | 120KVA | 132KVA | 6BTA5.9G2 | UCI 274D |
| W-DC150-1 | 150KVA | 148.5KVA | 6BTAA5.9G2 | UCI 274E |
| W-DC180M-1 | 180KVA | 198KVA | 6CTA8.3G1 | UCI 274G |
| W-DC180-1 | 180KVA | 198KVA | 6CTA8.3G2 | UCI 274G |
| W-DC200-1 | 200KVA | 220KVA | 6CTAA8.3G2 | UCD 274H |
| W-DC250-1 | 250KVA | 275KVA | 6LTAA8.9G2 | UCD 274K |
| W-DC300-1 | 300KVA | 330KVA | NTA855-G1A | UCD 444D |
| W-DC350-1 | 350KVA | 385KVA | NTA855-G2A | HCI 444E |
| W-DC400-1 | 400KVA | 440KVA | KTAA19-G2 | HCI 444F |
| W-DC450-1 | 450KVA | 495KVA | KTA19-G3 | HCI 544C |
| W-DC500M-1 | 500KVA | 550KVA | KTA19-G3A | HCI 544D |
| W-DC500-1 | 500KVA | 550KVA | KTA19-G4 | HCI 544D |
| W-DC550-1 | 550KVA | 605KVA | KTAA19-G5 | HCI 544E |
| W-DC600-1 | 600KVA | 660KVA | KTA19-G8 | HCI 544E |
| W-DC750-1 | 750KVA | 858KVA | KTA38-G2 | HCI 544F |
| W-DC800-1 | 800KVA | 891KVA | KTA38-G2B | HCI 634G |
| W-DC950-1 | 950KVA | 1034KVA | KTA38-G2A | HCI 634H |
| W-DC1000-1 | 1000KVA | 1100KVA | KTA38-G5 | HCI 634J |
| W-DC1200 | 1200KVA | 1265KVA | KTA38-G9 | LVI 634K |
| W-DC1400 | 1400KVA | 1650KVA | KTA50-G8 | PI 734B |
| W-DC1500 | 1500KVA | 1650KVA | KTA50-GS8 | PI 734C |
Parametri Technici 60Hz
| Modellum Generatoris | Generator (KVA) | Machina Cummins | Alternator Stamfordensis | Data Singularia | |
| Prim Power | Potestas Subsidiaria | Modelus Machinae | Modelus Alternatoris | ||
| W-DC25M-60 | 23KVA | 25KVA | 4B3.9G1 | PI 144D | Plura notitia technica disce |
| W-DC25-60 | 23KVA | 25KVA | 4B3.9G2 | PI 144D | Plura notitia technica disce |
| W-DC30M-60 | 30KVA | 31KVA | 4B3.9G1 | PI 144E | Plura notitia technica disce |
| W-DC30-60 | 30KVA | 31KVA | 4B3.9G2 | PI 144E | Plura notitia technica disce |
| W-DC39M-60 | 35KVA | 39KVA | 4BT3.9-G1 | PI 144G | Plura notitia technica disce |
| W-DC39-60 | 35KVA | 39KVA | 4BT3.9-G2 | PI 144G | Plura notitia technica disce |
| W-DC45M-60 | 45KVA | 48KVA | 4BT3.9-G1 | PI 144J | Plura notitia technica disce |
| W-DC45-60 | 45KVA | 48KVA | 4BT3.9-G2 | PI 144J | Plura notitia technica disce |
| W-DC75-60 | 70KVA | 77KVA | 4BTA3.9-G2 | UCI 224E | Plura notitia technica disce |
| W-DC125M-60 | 115KVA | 126.5KVA | 6BT5.9G1 | UCI 224C | Plura notitia technica disce |
| W-DC125-60 | 115KVA | 126.5KVA | 6BT5.9G2 | UCI 224C | Plura notitia technica disce |
| W-DC150-60 | 140KVA | 154KVA | 6BTA5.9G2 | UCI 274C | Plura notitia technica disce |
| W-DC160-60 | 140KVA | 154KVA | 6BTAA5.9G2 | UCI 274D | Plura notitia technica disce |
| W-DC220-60 | 200KVA | 220KVA | 6CTA8.3G2 | UCI 274F | Plura notitia technica disce |
| W-DC250-60 | 230KVA | 253KVA | 6CTAA8.3G2 | UCI 274G | Plura notitia technica disce |
| W-DC310-60 | 280KVA | 308KVA | 6LTAA8.9G2 | UCD 274J | Plura notitia technica disce |
| W-DC350-60 | 310KVA | 341KVA | NTA855-G1 | UCD 274K | Plura notitia technica disce |
| W-DC400-60 | 360KVA | 396KVA | NTA855-G1B | UCD 444D | Plura notitia technica disce |
| W-DC450-60 | 450KVA | 495KVA | NTA855-G3 | HCI 444ES | Plura notitia technica disce |
| W-DC500-60 | 500KVA | 550KVA | KTA19-G2 | HCI 444E | Plura notitia technica disce |
| W-DC600-60 | 600KVA | 660KVA | KTAA19-G3 | HCI 544C | Plura notitia technica disce |
| W-DC630-60 | 630KVA | 693KVA | KTA19-G3A | HCI 544D | Plura notitia technica disce |
| W-DC690-60 | 630KVA | 693KVA | KTA19-G5 | HCI 544E | Plura notitia technica disce |
| W-DC880-60 | 800KVA | 880KVA | KTA38-G | HCI 544F | Plura notitia technica disce |
| W-DC1030-60 | 940KVA | 1034KVA | KTA38-G2 | HCI 634G | Plura notitia technica disce |
| W-DC1090-60 | 1090KVA | 1199KVA | KTA38-G2A | HCI 634H | Plura notitia technica disce |
| W-DC1180-60 | 1180KVA | 1298KVA | KTA38-G4 | HCI 634J | Plura notitia technica disce |
| W-DC1500-60 | 1500KVA | 1650KVA | KTA38-G9 | LVI 634K | Plura notitia technica disce |
| W-DC1580-60 | 1580KVA | 1738KVA | KTA50-G9 | PI 734B | Plura notitia technica disce |
Detalia involucri:Involucrum generale vel capsa lignea compacta
Detalia traditionis:Intra decem dies post solutionem missum
1. Quid estambitus potentiaegeneratorum dieseliorum?
Potentia a 10kva ~ 2250kva variat.
2. Quid esttempus traditionis?
Traditio intra septem dies post depositum confirmatum.
3. Quid est tuum?terminus solutionis?
a. Accipimus 30% T/T ut depositum, reliquum solutum ante traditionem
bL/C ad conspectum
4. Quid estvoltatiogeneratoris tui dieseli?
Tensio electrica est 220/380V, 230/400V, 240/415V, sicut postulatio tua.
5. Quid est tuumtempus warantiae?
Tempus warantiae nostrae est unus annus vel mille horae operationis, quod prius advenerit. Sed pro aliquo opere speciali, tempus warantiae extendere possumus.












